# Redundancy (Systems)

> A spare of each key part, so one failure does not stop the system.

**Field:** Infrastructure  
**Category:** Reliability  
**Also known as:** Redundant System, N+1 Redundancy, Spare Capacity

## Think of it like

Think of it like carrying a spare tyre. You hope not to need it, but the trip goes on if you do.

## Definition

Redundancy means keeping more than one of each important part, so one can fail and the system still works. A server may have two power supplies and two network links. A service may run on three servers when two could carry the load. That setup is called N+1: the number you need, plus one spare. Redundancy costs money every day, to save you on the day something breaks.

## Example

Lucy's site needs two web servers to handle its traffic. She runs three, so one can fail or be updated while the other two carry on.

## Why it matters

Every part fails in the end. Without a spare, the first failure becomes an outage.

## Common mistake

Putting both copies in the same place. Two servers in one rack share one power feed, so one fault can take out both.

## Three principles

- **Spares.** More than one of each key part.
- **N+1.** What you need, plus one.
- **Spread them out.** Spares that share a fault are not spares.

## Related terms

- [High Availability (HA)](https://learn.benibix.com/term/infrastructure/high-availability)
- [Fault Tolerance](https://learn.benibix.com/term/infrastructure/fault-tolerance)
- [Failover](https://learn.benibix.com/term/infrastructure/failover)
- [Redundant Array of Independent Disks (RAID)](https://learn.benibix.com/term/infrastructure/raid)
- [Availability Zone](https://learn.benibix.com/term/infrastructure/availability-zone)
- [Single Point of Failure](https://learn.benibix.com/term/development/single-point-of-failure)
- [Redundant Power Supply](https://learn.benibix.com/term/infrastructure/redundant-power-supply)

## Told apart from

- [Redundancy vs Failover](https://learn.benibix.com/compare/redundancy-vs-failover): People think having a spare means the service stays up, and it does not on its own. Redundancy is owning the spare. Failover is the switch that moves the work to it when the main part dies. A spare that nothing switches to sits idle while the site is down, so the switch has to be built and tested too.

![Three panels. Redundancy: three web servers where two would do. Failover: a main database crossed out and an arrow moving traffic to a standby copy. Graceful degradation: a shop page with the suggestions box greyed out while the pay button still works.](https://learn.benibix.com/diagrams/inf4-failover.svg)

---

Source: https://learn.benibix.com/term/infrastructure/redundancy
Author: Behnia Zarei (a developer in Vienna, Austria, who builds and teaches data, AI and business intelligence at BENIBIX)
Publisher: BENIBIX Learn (https://learn.benibix.com/)
Last updated: 2026-11-19
Licence: CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Quote freely with attribution.