# Redundant Power Supply

> Two power supplies in one server. If one fails, the other carries on.

**Field:** Infrastructure  
**Category:** Servers  
**Also known as:** Dual Power Supply, Redundant PSU, Dual PSU

## Think of it like

Think of it like a plane with two engines. If one stops, the other keeps it flying.

## Definition

A redundant power supply means a server has two power supplies instead of one. Each one alone can run the whole server. If one breaks, the other takes over with no pause. Each is often plugged into a different power line. So the server stays on even when one line fails.

## Example

Emma's server has two power supplies on two power lines. One line trips during a repair, and the server never notices.

## Why it matters

Power supplies are one of the parts that fail most. A second one turns a crash into a quiet swap.

## Common mistake

Plugging both power supplies into the same power strip. If the strip fails, both go dark together.

## Three principles

- **Two of them.** Each can run the server alone.
- **No pause.** The spare takes over at once.
- **Two lines.** Plug each into its own power.

## Related terms

- [Hot Swapping](https://learn.benibix.com/term/infrastructure/hot-swapping)
- [Uninterruptible Power Supply (UPS)](https://learn.benibix.com/term/infrastructure/uninterruptible-power-supply)
- [Error-Correcting Code Memory (ECC Memory)](https://learn.benibix.com/term/infrastructure/ecc-memory)
- [Fault Tolerance](https://learn.benibix.com/term/infrastructure/fault-tolerance)

## Told apart from

- [Redundant Power Supply vs UPS](https://learn.benibix.com/compare/redundant-power-supply-vs-ups): People often think two power supplies keep a server on through a power cut. They do not. Two power supplies guard against one of them breaking. If the building loses power, both go dark at once. A UPS is a battery that carries the server through the cut. Most servers that must stay up have both.

## Taught in

- [Redundant Power and UPS](https://learn.benibix.com/learn/infrastructure-servers/redundant-power-and-ups): Servers and Racks, 6/8

![A rack server seen from the front and the back. The front shows a row of drive bays, one drive half pulled out while the server is on. The back shows two power supplies plugged into two separate power lines, network ports and one separate port marked BMC. Inside, memory sticks are marked ECC.](https://learn.benibix.com/diagrams/inf3-server-parts.svg)

---

Source: https://learn.benibix.com/term/infrastructure/redundant-power-supply
Author: Behnia Zarei (a developer in Vienna, Austria, who builds and teaches data, AI and business intelligence at BENIBIX)
Publisher: BENIBIX Learn (https://learn.benibix.com/)
Last updated: 2026-11-19
Licence: CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Quote freely with attribution.